Laboratory Development Pictures
Bolt Fixtures (5)


Blue => displacement (in); Red => force (lbf)
~ 4100 lb on the bolt, near failure point

DAQ with the analog output using
LabView & plotted on Excel,
1 data per 0.001" displacement

Tensile Strength of grade 5 bolt (N ~ 90)
from McMaster Carr, Su min. = 120 kpsi
Broke a box of bolts (N ~ 90).

SAE Grade 5 bolts, Su min. = 120 kpsi (99% of the fasteners need to exceed this value). You design against the weakest fastener, not against the average (~132 kpsi for this batch).


CAD model of the part
(done during design phase)

Cross-sectional view of the bolt